Both the Spectrum Trace and Smart Trace modes support importing a spectrum trace to be used during intermodulation analysis. Two formats are supported. The first follows the format used by Pro Audio White Space Finder (PAWS4400) to export spectrum traces -- the format of the XML file must obey the following schema:
<?xml version="1.0" encoding="us-ascii"?>
<paws4400-scans>
<spectrum-trace appid="1737" format="540" date="Friday, April 08, 2011" starttime="10:14:29" white-space-threshold="-55" startfreqhz="550000000" endfreqhz="650000000" pointspertrace="400" signal-strengths-dbm="-96,-98,-95,-93,-97,-95,-95,-97,-96,-93,-94,-94,-96,-95,-98,-97,-99,-96,-99,-97,-99,-95,-95,-94,-94,-97,-96,-97,-99,-98,-98,-96,-94,-90,-81,-80,-71,-67,-62,-56,-52,-48,-45,-40,-38,-36,-34,-32,-30,-30,-32,-34,-36,-38,-40,-44,-48,-52,-56,-59,-66,-73,-78,-82,-89,-98,-98,-99,-93,-95,-96,-94,-97,-97,-94,-98,-93,-93,-96,-98,-95,-93,-98,-97,-93,-96,-94,-98,-95,-99,-97,-95,-93,-99,-98,-96,-95,-99,-99,-98,-96,-96,-98,-96,-96,-93,-95,-99,-97,-97,-93,-99,-94,-98,-97,-93,-96,-95,-94,-99,-96,-98,-93,-97,-97,-99,-96,-96,-93,-96,-95,-96,-93,-87,-85,-76,-73,-68,-60,-55,-53,-48,-43,-40,-38,-36,-34,-32,-30,-30,-32,-34,-36,-38,-39,-45,-48,-52,-56,-60,-64,-70,-78,-82,-88,-96,-97,-96,-95,-97,-97,-98,-93,-98,-95,-93,-96,-98,-93,-98,-99,-96,-94,-93,-94,-93,-96,-96,-96,-96,-93,-96,-98,-94,-96,-93,-99,-97,-93,-99,-96,-96,-96,-95,-96,-98,-96,-94,-96,-94,-94,-99,-95,-93,-98,-94,-95,-97,-98,-94,-94,-95,-96,-94,-93,-97,-98,-99,-95,-95,-97,-94,-93,-93,-83,-77,-72,-68,-58,-56,-52,-48,-44,-40,-38,-36,-34,-32,-30,-30,-32,-34,-36,-38,-39,-44,-48,-52,-56,-61,-67,-73,-77,-81,-90,-98,-93,-96,-94,-93,-97,-98,-94,-97,-96,-97,-99,-95,-98,-95,-93,-95,-94,-96,-97,-97,-99,-97,-98,-99,-95,-96,-97,-93,-99,-96,-98,-93,-99,-96,-99,-96,-99,-93,-94,-93,-98,-93,-96,-98,-98,-95,-98,-96,-96,-96,-93,-96,-96,-98,-93,-93,-98,-94,-98,-97,-97,-96,-94,-96,-93,-96,-95,-89,-81,-79,-72,-65,-59,-57,-51,-49,-43,-41,-38,-36,-34,-32,-30,-30,-32,-34,-36,-38,-40,-43,-47,-52,-55,-59,-67,-74,-78,-86,-90,-97,-96,-94,-93,-94,-96,-95,-94,-96,-94,-96,-99,-96,-96,-95,-95,-96,-94,-96,-97,-96,-96,-93,-98,-98,-98,-99,-96,-99,-96,-96,-95,-96,-93,-96" />
</paws4400-scans>
And the second format uses comma-separated [frequency (MHz), amplitude (dBm)] pairs, similar to that shown below. The data exported by the Thurlby Thandar Instruments (TTI) PSA series hand-held spectrum analyzer is already in the correct format.
450.0000,-96.7
450.7813,-96.7
451.5625,-76.6
452.3438,-96.5
453.1250,-96.8
453.9063,-75.9
454.6875,-95.4
455.4688,-93.0
456.2500,-96.6
457.0313,-72.7
457.8125,-77.6
458.5938,-95.6
459.3750,-93.7
460.1563,-96.3
460.9375,-76.2
461.7188,-93.9
462.5000,-96.3
463.2813,-88.3
464.0625,-86.3
464.8438,-96.8
465.6250,-96.3
466.4063,-96.3
467.1875,-96.1
467.9688,-96.9
468.7500,-92.0